DMX Branch Lines

by Christian Marg <christian.marg@[EMAIL PROTECTED] > Apr 19, 2008 at 03:51 AM

Hello,

of course cabling DMX in a 'Y' shape is a big no, no, but since DMX is 
"just" RS485 and RS485 allows for unterminated branch lines up to 5 
Meters, maybe I could use 1m or so to connect a dimmer and save some 
connectors I'd need to use for daisy chaining. Couldn't I?

Or am I misreading RS485 and missing the note about "branch lines are 
only allowed for up to 1200 Baud"?

bye
Christian
 




 14 Posts in Topic:
DMX Branch Lines
Christian Marg <christ  2008-04-19 03:51:44 
Re: DMX Branch Lines
Torrance Bell <starlit  2008-04-18 23:37:28 
Re: DMX Branch Lines
"Duncan Wood" &  2008-04-19 11:47:22 
Re: DMX Branch Lines
whodewawhybot@[EMAIL PROT  2008-04-25 00:18:51 
Re: DMX Branch Lines
"Duncan Wood" &  2008-04-25 12:21:02 
Re: DMX Branch Lines
Torrance Bell <starlit  2008-04-25 06:52:05 
Re: DMX Branch Lines
Torrance Bell <starlit  2008-04-25 06:54:24 
Re: DMX Branch Lines
"Duncan Wood" &  2008-04-25 22:42:52 
Re: DMX Branch Lines
"John B" <sp  2008-04-26 16:09:47 
Re: DMX Branch Lines
Torrance Bell <starlit  2008-04-26 16:46:00 
Re: DMX Branch Lines
RickR <contact@[EMAIL   2008-04-28 10:46:07 
Re: DMX Branch Lines
Torrance Bell <starlit  2008-04-28 16:00:38 
Re: DMX Branch Lines
"Duncan Wood" &  2008-04-28 22:31:53 
Re: DMX Branch Lines
Torrance Bell <starlit  2008-04-28 17:52:02 